Nominal capacities in the catalog are given according to T1 as defined in EN 328 standard conditions of Eurovent
∆T1 = (Room Temp.) – (Evaporation Temp.)
Table – 1 Standard Conditions (Eurovent EN 328)
Nominal capacities in the catalog are given according to T1 as defined in EN 328 standard conditions of Eurovent
∆T1 = (Room Temp.) – (Evaporation Temp.)
Table – 1 Standard Conditions (Eurovent EN 328)
Standard Conditions For Refrigerants | Room Temperature Degree C | Evaporating Temperature Degree C |
---|---|---|
SC1 | 10 | 0 |
SC2 | 0 | -8 |
SC3 | -18 | -25 |
SC4 | -25 | -31 |
Recommended Efficient Fin Spacings According to Room Temperatures
Eurovent 328 Standard | Fin Spacing | Room Temperature (T1) |
---|---|---|
SC1 | 4mm ~ 6mm | 10 degree C |
SC2 | 6mm ~ 6mm | 0 degree C |
SC3 | 8mm ~ 100mm | -18 degree C |
SC4 | 10mm | -25 degree C |